ANALYSIS AND DESIGN OF RESIDENTIAL BUILDING OF 2BHK UNDER GHMC
Abstract
The project comprises the development of plans, elevations, and sectional view of a
Residential Reinforced Concrete building of ground floor, using Auto-cad 2008. Structural loads
(Gravitational loads only), Dead and Live loads are only considered for the design of structure, and the
loads considered are as per IS: 875 – Part-I & II. The analysis and design of the building skeletal fame is
performed by using STAAD Pro V8i package for factored (Limit state of strength) combination(s). The
structural displacements in vertical and horizontal directions of the building are permitted to the
limitations as per IS: 456 – 2000, for un-factored (Limit state of serviceability) combination(s). Structural
elements like Slab(s) are designed manually and foundation design is done using STAAD foundation. The
reinforcement details are furnished according to the codal provisions and presented in this report.