Analysis & Design Of Earthquake Resistant (C+G+10) Using E-Tabs
Keywords:
Building, Earth quake, ETABSAbstract
The main steps of any building construction and planning is drafting, analyzing and designing the building. In the present days of improving science and technology, analyzing and designing of a building has been made easy by using ETABS software. ETABS software helps civil engineers to make their work easy and decreases time necessary for planning.
The project going to be done is design of a multi-story building which is going to be used as a residential. The building plan has been drafted using the AutoCAD software by the requirement and available area. The super structure i.e., the building frame has been analyzed and designed using the ETABS software.In the present project C+G+10 building considers to analysis and design for both gravity and lateral (wind and earth quake) loads as per Indian standards.
By using the software building can be analyzed and we can check for any failures in the analysis and redesign them, so that we can prevent failures after construction. By using the output building can be constructed according to the design.
Downloads
References
Abhay Guleria (2014) : Structural Analysis of a Multi-Storeyed Building Using ETABS for different Plan Configurations”, International Journal of Engineering Research & Technology (IJERT), Vol. 3 Issue 5, May 2014
2. Raghunandan MH and Suma (2015):Seismic Pounding between Adjacent RC Buildings with and without Base IsolationSystem,International Journal of Research in Engineering and Technology, Volume: 04 Issue: 06 | June-2015.
3. Sukumar Behera (2012) : Seismic Analysis of Multi-storey Buildingwith Floating Column, National Institute of TechnologyRourkela, May-2012.
4. Mr.N.B.Baraskar&Prof.U.R.Kawade (2015) : Structural Performance of RC Structural wall system Over conventional BeamColumn System in G +15 storey Building”, International Journal of Engineering Research and General Science Volume 3, Issue 4, July-August, 2015,
5. Miss. Rupali A.Dhote, Asst. Prof. G. B. Bhaskar (2016) : Design& Analysis of Soft Storey Building due to wind & Earthquake”, International Journal for Technological Research in Engineering Volume 3, Issue 9, May-2016.
6. Hiten L. Kheni, Anuj K. Chandiwala(2014): Seismic Response of RC Building with Soft Stories”, International Journal of Engineering Trends and Technology (IJETT) Volume 10 Number 12 - Apr 2014
7. Sagar R Padol, Rajashekhar S. Talikoti (2015): Review Paper on Seismic Responses of Multi-story R.c.c Building with Mass Irregularity”, IJRET: International Journal of Research in Engineering and Technology, Volume: 04 Issue: 03 | Mar -2015.
8. D. R. Panchal and P. M. Marathe (2011): Comparative Study of R.C.C, Steel and Composite (G+30 Storey) Building”, Institute of Technology, Nirma University, Ahmadabad, December, 2011.